大秀视频

As 大秀视频 HeartMates Grows, Personal Connections Do Too

Our team of heart health heroes expands by 11 鈥渄raft picks,鈥 each with an inspiring comeback story.

Abe

Healthy Heart|May 22, 2025

This is how you build a heart health dynasty.

While pro football teams were drafting new players in hopes of creating a winning team, the 大秀视频 HeartMates program continued adding heart health champions to our already strong roster.

We welcomed 11 new teammates during our HeartMates Draft event over three days in April 鈥 ranging from a rodeo champion who recovered from a stroke to a bracelet-making 11-year-old who is thriving after receiving a heart transplant.

The connection they now share is what our heart health-focused program is all about. Ever since HeartMates kicked off in 2023, members have told us over and over again that being able to share their stories with others who know what they鈥檙e going through truly makes the program meaningful. With every new addition to the team, these special bonds grow stronger.

This latest class of draftees found out they made the team thanks to surprise calls from none other than current pro football player Damar Hamlin and retired pro Tedy Bruschi, our 大秀视频 HeartMates ambassadors.

Like Hamlin and Bruschi, each of these 11 new teammates has shown extraordinary courage in either coming back from a heart-related setback or managing a heart condition while they pursue their dreams.

Introducing our 2025 HeartMates Draft picks:

Stran Smith, a rancher and 2008 rodeo world champion from Childress, Texas, had a stroke at age 32 caused by a patent foramen ovale (PFO) 鈥 an opening between the right and left sides of the upper chambers of the heart. He received an and is back to working his ranch with his wife and three children. Smith has also shared his story in a new book.

Jaden Hartley, of Chicago, joins the HeartMates team about a year after meeting program ambassador Damar Hamlin while he was in the hospital. Hartley had gone into heart failure while on vacation in Hawaii and was airlifted back home. He received 大秀视频鈥檚 and then successfully underwent a heart transplant. Now back at school, he鈥檚 picking up a basketball again and inspiring others after an incredible journey.

Heather Strong, of New Boston, N.H., had a hole in her heart, and so did her two daughters. Strong, as her name suggests, fought her way back from two strokes, the first of which happened in late 2023. Her and her daughters鈥 hearts were repaired with , and all three are now living active, sports-filled lives.

Bao Lee, of Brooklyn Park, Minneapolis, has a heart health story rooted in family. Her mother works at 大秀视频 on the team that built the that was implanted in Bao to help treat an atrial septal defect (ASD). After undergoing the treatment, Lee got her health back and grew her family to five wonderful children.

Ashley Greiner, an attorney and athlete from Elbridge, N.Y., found herself dealing with exhaustion and swollen feet at age 35. An emergency room visit resulted in a diagnosis of heart failure. In 2017, she received the , and since then Ashley has been able to put back together a new life for herself, including running a support group for others impacted by heart issues, traveling and speaking courageously about her journey.

Joe Maniaci, of Macomb, Mich., was a freshman at the University of Michigan when he started experiencing chronic fatigue so severe it impacted his grades. People around him said it must be a cold or just too many first-year hijinks, but a checkup turned into a nine-day hospital stay and diagnosis of congestive heart failure. Maniaci received a and went on to earn a master鈥檚 degree in 2020 before starting medical school. He now works as a clinical research coordinator at Henry Ford Health System and is an active patient ambassador for people considering or new to LVAD therapy.

Lynda Marino is a wife and mother of two from East Amherst, N.Y., who experienced cardiac arrest while driving on a busy highway in 2017 and was saved by complete strangers who performed CPR until assistance arrived. After numerous surgeries and procedures, she received 大秀视频鈥檚 AVEIR DR dual chamber leadless pacemaker system in 2023 and is back to living a busy life.

For Jessica Lertzman, of听Center Valley, Penn., heart health carries twice the significance: She and her twin sister both have overcome heart rhythm conditions in order to be where they are today. Now with an 大秀视频 Gallant CRT-D device, this mother and busy fourth-grade teacher (who has incorporated Hamlin into some of her lessons) has drawn on her experience to be an advocate for the HeartMates program.

Tom Hulsey, of Dallas, will be the first to tell you that having three life-threatening illnesses has given him a wonderful perspective on life and a purpose. Hulsey shares his inspiring story 鈥 a journey that has included coronary artery disease and arrhythmia 鈥 as a reminder that cardiovascular disease can still impact you even if you compete in the Iron Man World Championship.

Former weightlifter Tara Benoit, an executive recruiter from Windham, N.H., began her comeback story after suffering a spontaneous coronary artery dissection after a case of COVID-19. Now, she鈥檚 managing her condition while getting back to yoga, walking and being a working mom to two football-loving sons.

Olivea Hannah, an 11-year-old from Austin, Texas, and the recent recipient of a heart transplant, has a talent for lifting up others with the friendship bracelets she makes. A few of those bracelets made their way to HeartMates program ambassador Damar Hamlin,

To learn more about the program and find out how you can join the team, too, visit our 大秀视频 HeartMates page.

Important safety information

HEARTMATE II鈩 LEFT VENTRICULAR ASSIST SYSTEM

HEARTMATE 3鈩 LEFT VENTRICULAR ASSIST SYSTEM

CARDIOMEMS HF SYSTEM

GALLANT/ENTRANT ICDS AND CRT-DS听

AVEIR鈩 DR Dual Chamber Leadless Pacemaker System

AMPLATZER鈩 SEPTAL OCCLUDER AND DELIVERY SYSTEM

Rx Only

INDICATION FOR USE

The AMPLATZER鈩 Septal Occluder is a percutaneous, transcatheter, atrial septal defect closure device intended for the occlusion of atrial septal defects (ASD) in secundum position or patients who have undergone a fenestrated Fontan procedure and who now require closure of the fenestration. Patients indicated for ASD closure have echocardiographic evidence of ostium secundum atrial septal defect and clinical evidence of right ventricular volume overload (such as, 1.5:1 degree of left-to-right shunt or RV enlargement).

CONTRAINDICATIONS

The AMPLATZER鈩 Septal Occluder is contraindicated for the following:

  • Any patient known to have extensive congenital cardiac anomaly which can only be adequately repaired by way of cardiac surgery.
  • Any patient known to have sepsis within 1 month prior to implantation, or any systemic infection that cannot be successfully treated prior to device placement.
  • Any patient known to have a bleeding disorder, untreated ulcer, or any other contraindications to aspirin therapy, unless another antiplatelet agent can be administered for 6 months.
  • Any patient known to have a demonstrated intracardiac thrombi on echocardiography (especially left atrial or left atrial appendage thrombi).
  • Any patient whose size (such as, too small for transesophageal echocardiography probe, catheter size) or condition (active infection, etc.) would cause the patient to be a poor candidate for cardiac catheterization.
  • Any patient where the margins of the defect are less than 5 mm to the coronary sinus, inferior vena cava rim, AV valves, or right upper lobe pulmonary vein.

WARNINGS

  • Physicians must be prepared to deal with urgent situations, such as device embolization, which require removal of the device. This includes the availability of an on-site surgeon.
  • Embolized devices must be removed as they may disrupt critical cardiac functions. Embolized devices should not be withdrawn through intracardiac structures unless they have been adequately collapsed within the sheath.
  • Use on or before the expiration date noted on the product packaging.
  • This device is sterilized using ethylene oxide and is for single use only. Do not reuse or resterilize. Attempts to resterilize the device may result in device malfunction, inadequate sterilization, or patient harm.
  • Do not use the device if the packaging sterile barrier is open or damaged.
  • Do not release the AMPLATZER鈩 Septal Occluder from the delivery cable if the device does not conform to its original configuration, or if the device position is unstable or if the device interferes with any adjacent cardiac structure (such as Superior Vena Cava (SVC), Pulmonary Vein (PV), Mitral Valve (MV), Coronary Sinus (CS), aorta (AO)). Recapture the device and redeploy. If still unsatisfactory, recapture the device and either replace with a new device or refer the patient for alternative treatment.
  • Implantation of this device may not supplant the need for Coumadin鈩 in patients with ASD and paradoxical emboli.
  • The use of echocardiographic imaging (TTE, TEE, or ICE) is required.
  • Balloon sizing should be used to size the atrial septal defect using a stop-flow technique. Do not inflate the balloon beyond the cessation of the shunt (such as, stop-flow). DO NOT OVERINFLATE.
  • Patients with a retro-aortic rim of less than 5 mm in any echocardiographic plane, or patients in whom the device physically impinges on (i.e. indents or distorts) the aortic root, may be at increased risk of erosion.
  • Do not select a device size greater than 1.5 times the echocardiographic-derived ASD diameter prior to balloon sizing.

PRECAUTIONS

  • The use of this device has not been studied in patients with patent foramen ovale.
  • Use standard interventional cardiac catheterization techniques to place this device.
  • Placement of the AMPLATZER鈩 Septal Occluder may impact future cardiac interventions, for example transeptal puncture and mitral valve repair.
  • This device contains nickel-titanium alloy, which is generally considered safe. However, in vitro testing has demonstrated that nickel is released from this device for a minimum of 60 days. Patients who are allergic to nickel may have an allergic reaction to this device, especially those with a history of metal allergies. Certain allergic reactions can be serious; patients should be instructed to seek medical assistance immediately if they suspect they are experiencing an allergic reaction. Symptoms may include difficulty in breathing or swelling of the face or throat. While data is currently limited, it is possible that some patients may develop an allergy to nickel if this device is implanted.

MR Conditional to 3.0 Tesla

Caution should be used if an MRI is performed with a magnetic field of >3.0 tesla. Through non-clinical testing, the AMPLATZER鈩 device has been known to be MR Conditional at field strengths of 3.0 tesla or less with a maximum whole-body-averaged specific absorption rate (SAR) of 3.83 W/kg at 1.5 tesla and 5.57 W/kg at 5.0 tesla for a 20-minute exposure to a B1 of 118 渭T. The AMPLATZER鈩 device should not migrate in this MR environment. Non-clinical testing has not been performed to rule out the possibility of migration at field strengths higher than 3.0 tesla. In this testing, the device produced a temperature rise of 1.1掳C at 1.5 tesla and 1.6掳C at 5.0 tesla. MR image quality may be compromised if the area of interest is in the exact same area or relatively close to the position of the device.

POTENTIAL ADVERSE EVENTS

Potential adverse events may occur during or after a procedure placing this device may include, but are not limited to:

Air embolus; Allergic dye reaction; Anesthesia reactions; Apnea; Arrhythmia; Cardiac tamponade; Death; Embolization; Fever; Hypertension/ hypotension; Infection including endocarditis; Need for surgery; Pericardial effusion; Perforation of vessel or myocardium; Pseudoaneurysm including blood loss requiring transfusion; Stroke; Tissue erosion; Thrombus formation on discs; Valvular regurgitation.

AMPLATZER鈩 TALISMAN鈩 PFO OCCLUDER

Rx Only

Indications for Use

The AMPLATZER鈩 PFO Occluder is indicated for percutaneous transcatheter closure of a patent foramen ovale (PFO) to reduce the risk of recurrent ischemic stroke in patients, predominantly between the ages of 18 and 60 years, who have had a cryptogenic stroke due to a presumed paradoxical embolism, as determined by a neurologist and cardiologist following an evaluation to exclude known causes of ischemic stroke.

CONTRAINDICATIONS

Patients with intra-cardiac mass, vegetation, tumor or thrombus at the intended site of implant, or documented evidence of venous thrombus in the vessels through which access to the PFO is gained; Patients whose vasculature, through which access to the PFO is gained, is inadequate to accommodate the appropriate sheath size; Patients with anatomy in which the AMPLATZER鈩 PFO device size required would interfere with other intracardiac or intravascular structures, such as valves or pulmonary veins; Patients with other source of right-to-left shunts, including an atrial septal defect and/or fenestrated septum; Patients with active endocarditis or other untreated infections

POTENTIAL COMPLICATIONS AND ADVERSE EVENTS

Potential adverse events that may occur during or after a procedure using this device may include, but are not limited to: Air embolus; Allergic drug reaction; Allergic dye reaction; Allergic metal reaction: Nitinol (nickel, titanium), platinum/iridium, stainless steel (chromium, iron, manganese, molybdenum, nickel); Anesthesia reactions; Apnea; Arrhythmia; Bacterial endocarditis; Bleeding; Brachial plexus injury; Cardiac perforation; Cardiac tamponade; Cardiac thrombus; Chest pain; Device embolization; Device erosion; Deep vein thrombosis; Death; Endocarditis; Esophagus injury; Fever; Headache/migraine; Hypertension/hypotension; Myocardial infarction; Pacemaker placement secondary to PFO device closure; Palpitations; Pericardial effusion; Pericardial tamponade; Pericarditis; Peripheral embolism; Pleural effusion; Pulmonary embolism; Reintervention for residual shunt/device removal; Sepsis; Stroke; Transient ischemic attack; Thrombus; Valvular regurgitation; Vascular access site injury; Vessel perforation.

HEARTMATE II鈩 LEFT VENTRICULAR ASSIST SYSTEM

Rx Only

Brief Summary:听Prior to using these devices, please review the Instructions For Use for a complete listing of indications, contraindications, warnings, precautions, potential adverse events and directions for use.

Indications:听The HeartMate II鈩 Left Ventricular Assist System is indicated for use as a 鈥渂ridge to transplantation鈥 for cardiac transplant candidates who are at risk of imminent death from non-reversible left ventricle failure. It is also indicated for use in patients with New York Heart Association (NYHA) Class IIIB or IV end-stage left ventricular failure, who have received optimal medical therapy for at least 45 of the last 60 days, and who are not candidates for cardiac transplantation. The HeartMate II Left Ventricular Assist System is intended for use both inside and outside of the hospital, or for transportation of Left Ventricular Assist Device patients via ground ambulance, airplane, or helicopter.

Contraindications:听The HeartMate II Left Ventricular Assist System is contraindicated for patients who cannot tolerate, or who are allergic to, anticoagulationtherapy.

Adverse Events:听Adverse events that may be associated with the use of the HeartMate II Left Ventricular Assist System are listed below. Adverse events are listed in decreasing order of frequency, except for death, which appears first because it is a non-reversible complication:Death, Bleeding (perioperative or late), Cardiac arrhythmia, Local infection, Respiratory failure, Device malfunction, Sepsis, Right heart failure, Driveline or pump pocket infection, Renal failure, Stroke, Neurologic dysfunction, Psychiatric episode, Peripheral thromboembolic event, Hemolysis, Hepatic dysfunction, Device thrombosis, Myocardial infarction.

HEARTMATE 3鈩 LEFT VENTRICULAR ASSIST SYSTEM

Rx Only

Brief Summary:听Prior to using these devices, please review the Instructions For Use for a complete listing of indications, contraindications, warnings, precautions, potential adverse events and directions for use.

Indications:听The HeartMate 3鈩 Left Ventricular Assist System is indicated for providing short- and long-term mechanical circulatory support (e.g., as bridge to transplant or myocardial recovery, or destination therapy) in adult and pediatric patients with advanced refractory left ventricular heart failure听and with an appropriate body surface area.

Contraindications:听The HeartMate 3 Left Ventricular Assist System is contraindicated for patients who cannot tolerate, or who are allergic to, anticoagulation therapy.

Adverse Events:听Adverse events that may be associated with the use of the HeartMate 3 Left Ventricular Assist System are: death, bleeding, cardiac arrhythmia, localized infection, right heart failure, respiratory failure, device malfunctions, driveline infection, renal dysfunction, sepsis, stroke, other neurological event (not stroke-related), hepatic dysfunction, psychiatric episode, venous thromboembolism, hypertension, arterial non-central nervous system (CNS) thromboembolism, pericardial fluid collection, pump pocket or pseudo pocket infection, myocardial infarction, wound dehiscence, hemolysis (not associated with suspected device thrombosis) or pump thrombosis.

HeartMate 3 Coring Tool

Indications:听For the HeartMate 3 Left Ventricular Assist System (LVAS) Indications for Use, please refer to the HeartMate 3 LVAS Instructions for Use. The HeartMate 3鈩 Coring Tool is intended for use with the HeartMate 3 LVAS. The HeartMate 3 Coring Tool provides a means to resect a plug of myocardium from the left ventricle, which allows for HeartMate 3 inflow cannula insertion.

Contraindications:听The use of the HeartMate 3 Coring Tool is contraindicated in patients who are contraindicated for HeartMate 3 Left Ventricular Assist System (LVAS) therapy.

Adverse Events:听The following adverse events may be associated with the use of the HeartMate 3 Coring Tool. Adverse events are listed in anticipated decreasing order of frequency, except for death, which appears first as it is a non-reversible complication: death, bleeding (perioperative or late), local infection, local ischemia, cardiac arrhythmia, stroke, peripheral thromboembolic event, neurologic dysfunction, hemolysis, sepsis.

CARDIOMEMS HF SYSTEM

Rx Only

Brief Summary:听Prior to using these devices, please review the Instructions for Use for a complete listing of indications, contraindications, warnings, precautions, potential adverse events and directions for use.

CardioMEMS HF System Indications and Usage:听The CardioMEMS HF System is indicated for wirelessly measuring and monitoring pulmonary artery pressure and heart rate in NYHA Class II or III heart failure patients who either have been hospitalized for heart failure in the previous year and/or have elevated natriuretic peptides. The hemodynamic data are used by physicians for heart failure management with the goal of controlling pulmonary artery pressures and reducing heart failure hospitalizations.

CardioMEMS HF System Contraindications:听The CardioMEMS HF System is contraindicated for patients with an inability to take dual antiplatelet or anticoagulants for one month post implant.

CardioMEMS HF System Potential Adverse Events:听Potential adverse events associated with the implantation procedure include, but are not limited to, the following: air embolism, allergic reaction, infection, delayed wound healing, arrhythmias, bleeding, hemoptysis, hematoma, nausea, cerebrovascular accident, thrombus, cardiovascular injury, myocardial infarction, death, embolization, thermal burn, cardiac perforation, pneumothorax, thoracic duct injury and hemothorax.

GALLANT/ENTRANT ICDS AND CRT-DS听

Rx Only

Brief Summary:听Prior to using these devices, please review the Instructions for Use for a complete listing of indications, contraindications, warnings, precautions, potential adverse events and directions for use.

Intended Use:听The Implantable Cardioverter Defibrillator (ICD) and Cardiac Resynchronization Therapy Defibrillator (CRT-D) devices are primarily intended for use with compatible leads detect and treat life threatening ventricular arrhythmias by providing ventricular antitachycardia pacing and ventricular cardioversion/defibrillation. In addition, these devices can detect and treat: chronic symptomatic bradyarrhythmia by providing sensing and pacing in the right ventricle; various atrioventricular conduction abnormalities by providing sensing and pacing in the right ventricle and/or right atrium. CRT-D devices sense cardiac activity and provide pacing to resynchronize the right and left ventricles.听听

The myMerlinPulse鈩 mobile application is intended for use by people who have an 大秀视频 Medical implanted heart device and access to a mobile device. The app provides remote monitoring capability of the implanted heart device by transmitting information from the patient鈥檚 implanted heart device to the patient鈥檚 healthcare provider.

Indications:听The ICD devices are indicated in patients who have already survived a cardiac arrest or are at a high risk of Sudden Cardiac Death (SCD) due to VT (ventricular tachycardia) or VF (ventricular fibrillation). Cardiac Resynchronization Therapy (CRT) devices are indicated for reduction of symptoms in patients who have congestive heart failure, a reduced left ventricular ejection fraction (LVEF) and a prolonged QRS duration. CRT-D devices are indicated in patients who meet the CRT indications and have already survived a cardiac arrest or are at a high risk of Sudden Cardiac Death (SCD) due to VT (ventricular tachycardia) or VF (ventricular fibrillation). The device is most commonly implanted within a device pocket in the pectoral region.听

The myMerlinPulse鈩 mobile application is indicated for use by patients with supported 大秀视频 Medical implanted heart devices.

Contraindications:听Contraindications for use of the pulse generator system include ventricular tachyarrhythmias resulting from transient or correctable factors such as drug toxicity, electrolyte imbalance, or acute myocardial infarction.听

The myMerlinPulse鈩 mobile application is contraindicated for use with any implanted medical device other than supported 大秀视频 Medical implanted heart devices.

Adverse Events:听Possible adverse events associated with the implantation of the pulse generator system include the following: Arrhythmia (for example, accelerated or induced), Bradycardia, Cardiac or venous perforation, Cardiac tamponade, Cardiogenic shock, Death, Discomfort, Embolism, Endocarditis, Erosion, Exacerbation of heart failure, Excessive fibrotic tissue growth, Extracardiac stimulation (phrenic nerve, diaphragm, pectoral muscle), Extrusion, Fluid accumulation within the device pocket, Formation of hematomas, cysts, or seromas, Heart block, Hemorrhage, Hemothorax, Hypersensitivity, including local tissue reaction or allergic reaction, Infection, Keloid formation, Myocardial damage, Nerve damage, Occlusion/Thrombus, Pericardial effusion, Pericarditis, Pneumothorax, Pulmonary edema, Syncope, Thrombosis, Valve damage. Complications reported with direct subclavian venipuncture include pneumothorax, hemothorax, laceration of the subclavian artery, arteriovenous fistula, neural damage, thoracic duct injury, cannulation of other vessels, massive hemorrhage and rarely, death. Among the psychological effects of device implantation are imagined pulsing, depression, dependency, fear of premature battery depletion, device malfunction, inappropriate pulsing, shocking while conscious, or losing pulse capability. Possible adverse device effects include complications due to the following: Abnormal battery depletion, Conductor fracture, Device-programmer communication failure, Elevated or rise in defibrillation/cardioversion threshold, Inability to defibrillate or pace, Inability to interrogate or program due to programmer or device malfunction, Incomplete lead connection with pulse generator, Inhibited therapy including defibrillation and pacing, Inappropriate therapy (for example, shocks and antitachycardia pacing [ATP] where applicable, pacing), Interruption of function due to electrical or magnetic interference, Intolerance to high rate pacing (for example dyspnea or discomfort), Lead abrasion, Lead fracture, Lead insulation damage, Lead migration or lead dislodgement, Loss of device functionality due to component failure, Pulse generator migration, Rise in DFT threshold, Rise in pacing threshold and exit block, Shunting of energy from defibrillation paddles, System failure due to ionizing radiation. Additionally, potential adverse events associated with the implantation of a coronary venous lead system include the following: Allergic reaction to contrast media, Breakage or failure of implant instruments, Prolonged exposure to fluoroscopic radiation, Renal failure from contrast media used to visualize coronary veins.听听

No potential adverse events have been identified with use of the myMerlinPulse鈩 mobile application.

AVEIR鈩 DR Dual Chamber Leadless Pacemaker System

Rx Only

Brief Summary:听Prior to using these devices, please review the Instructions for Use for a complete listing of indications, contraindications, warnings, precautions, potential adverse events and directions for use.

Indications:听The AVEIR鈩 Leadless Pacemaker system is indicated for management of one or more of the following permanent conditions: Syncope, Pre-syncope, Fatigue, Disorientation. Rate-modulated pacing is indicated for patients with chronotropic incompetence, and for those who would benefit from increased stimulation rates concurrent with physical activity. Dual-chamber pacing is indicated for patients exhibiting: Sick sinus syndrome, Chronic, symptomatic second- and third-degree AV block, Recurrent Adams-Stokes syndrome, Symptomatic bilateral bundle-branch block when tachyarrhythmia and other causes have been ruled out. Atrial pacing is indicated for patients with: Sinus node dysfunction and normal AV and intraventricular conduction systems. Ventricular pacing is indicated for patients with: Significant bradycardia and normal sinus rhythm with only rare episodes of AV block or sinus arrest, Chronic atrial fibrillation, Severe physical disability. MR Conditional: The AVEIR Leadless Pacemaker is conditionally safe for use in the MRI environment and according to the instructions in the MRI-Ready Leadless System Manual.

Intended Use:听The AVEIR Leadless Pacemaker (LP) is designed to provide bradycardia pacing as a pulse generator with built-in battery and electrodes for implantation in the right ventricle and/or right atrium. The LP is intended to provide sensing of intrinsic cardiac signals and delivery of cardiac pacing therapy within the implanted chamber for the target treatment group. The LP is also intended to operate optionally with another co-implanted LP to provide dual-chamber pacing therapy.

The AVEIR鈩 Delivery Catheter is intended to be used in the peripheral vasculature and the cardiovascular system to deliver and manipulate an LP. Delivery and manipulation includes implanting an LP within the target chamber of the heart.

Contraindications:听Use of the AVEIR Leadless Pacemaker is contraindicated in these cases:

Use of any pacemaker is contraindicated in patients with a co-implanted ICD because high-voltage shocks could damage the pacemaker and the pacemaker could reduce shock effectiveness.

Single-chamber ventricular demand pacing is relatively contraindicated in patients who have demonstrated pacemaker syndrome, have retrograde VA conduction, or suffer a drop in arterial blood pressure with the onset of ventricular pacing.

Programming of rate-responsive pacing is contraindicated in patients with intolerance of high sensor driven rates.

Use is contraindicated in patients with an implanted vena cava filter or mechanical tricuspid valve because of interference between these devices and the delivery system during implantation.

Persons with known history of allergies to any of the components of this device may suffer an allergic reaction to this device. Prior to use on the patient, the patient should be counseled on the materials (listed in the Product Materials section of the IFU) contained in the device and a thorough history of allergies must be discussed.

Adverse Events:听Potential complications associated with the use of the AVEIR Leadless Pacemaker system are the same as with the use of single or dual chamber pacemakers with active fixation pacing leads including, but not limited to: Cardiac perforation, Cardiac tamponade, Pericardial effusion, Pericarditis, Endocarditis, Valve damage or regurgitation, Heart failure, Pneumothorax/hemothorax, Cardiac arrhythmias, Diaphragmatic/phrenic nerve stimulation / extra-cardiac stimulation, Palpitations, Hypotension, Syncope, Cerebrovascular accident, Infection, Hypersensitivity reaction to device materials, contrast media, medications, or direct toxic effect of contrast media on kidney function, Pacemaker syndrome, Inability to interrogate or program the LP due to programmer or LP malfunction, Intermittent or complete loss of capture, pacing or sensing (non-battery related), Oversensing, Increased capture threshold, Inappropriate sensor response, Corrupted, intermittent, or loss of i2i communications, Interruption of desired LP function due to electrical interference, either electromyogenic or electromagnetic, Battery malfunction/ premature battery depletion, Device-related complications (Premature deployment, Device dislodgement/embolization of foreign material, Inability to release/re-dock of the LP from the catheter, Helix distortion), Additional surgery or intervention, Death. As with any percutaneous catheterization procedure, potential complications include, but are not limited to: Vascular access complications; such as perforation, dissection, puncture, groin pain, Bleeding or hematoma, Thrombus formation, Thromboembolism, Air embolism, Local and systemic infection, Peripheral nerve damage. General surgery risks and complications from comorbidities; such as dyspnea, respiratory failure, pneumonia, hypertension, cardiac failure, reaction to sedation, renal failure, anemia, and death.